Definition Of Program Parameters
Open File
This is to open profile
Store File
This is to save profile
Open Root
This is to set the path to open files
Store Root
This is to set the path for saved files
Comm Num
This is to set the assigned com port from the Windows Device Manager > You can find out by open Control Panel > Phone and Modem Options
Start Transmit
This is to send the parameters to the controller flash memory
a) When ready to send the settings over
to the controller, click Start Transmit on the program. Press the button on the USB-TTL adapter and hold it for 5 seconds after you
clicked on the Start Transmit
b) You will see the result/feedback from the status box on the program
indicating it has been transmitted successfully with an OK.
c) Click on the Stop Transmit on the program
d) Disconnect the USB-TTL programming adapter into the JST-SM 5 pins connector on the controller's end
e) Disconnect the USB-TTL programming adapter from your PC
f) Close the program
______________________________
Board Type
This is to select the controller board you have:
a) EB206 = 6 FET controller board
b) EB209 = 9 FET controller board
c) EB212 = 12 FET controller board
d) EB218 = 18 FET controller board
e) EB224 = 24 FET controller board
______________________________
Current\Voltage Design
Phase Degree
Motor hall/phase degree > 0 = 120 degree, 1 = 60 degree, 2 = auto select (auto select may not be compatible with certain type of motors)
Phase Current (A)
Motor phase current
Rated Current (A)
Battery to controller current
Halt Voltage (V)
Low voltage cutoff
Tolerance (V)
Allowable voltage differences before the controller protection circuitry is enable to avoid damage
EBS LimVolage (V)
Regenerative Braking Voltage > 55v, 60v, 75v
______________________________
Speed Mode (optional)
Limit Speed
Limiting speed in percentage
Speed Mode
Choose switch mode if the three way switch is being used
Speed 1
Limiting speed in percentage for speed mode 1
Speed 2
Limiting speed in percentage for speed mode 2
Speed 3
Limiting speed in percentage for speed mode 3
Indicate Mode
not in use
Converse Speed
Limiting reverse speed in percentage
______________________________
Time \ Others
Block Time (s) in second when to trigger the overload protection when the controller senses overload. It is recommended to set it at 1 second so the controller can protect itself from being damaged as soon as it senses overload.
This option tells the controller
Auto Cruising Time (s) (optional)
This is to enable software featured cruise control in second. For example, when set to second 10; the throttle will stay at the throttle speed when you hold the throttle for 10 second. This feature is not enable and not recommended due to liability reason.
Slip Charge Mode (optional)
This is to enable the regenerative braking at speed 15 KPH/10MPH or above (0 = ON, 1 = OFF)
EBS Level (optional)
This is to select the strength of electric braking system
______________________________
Guard Level (optional)
This is a security feature to prevent the electric bike to stolen by applies electric lock on the hub motor so the motor cannot be push forward or backward easily
Bar Protect
This is to protect the throttle if it senses irregular voltage to prevent throttle from getting damage.
1:1 Design (optional)
This is for use with the pedal assist system, (PAS) module only.
P3 Design (optional)
not in use